CML12-DP256 Monitor version 2.5 update instructions
08142002

This document and accomanying S record file (12L2p5up.s19) provides
a Monitor version update to correct utility trace operation problems
in earlier monitor versions.

DO NOT DEVIATE FROM THE PROCEDURE!!!

Update procedure:

1) Reset CML12-DP256 board and start current monitor.

2) Perform command:  BF 4000 7FFF FF<enter
This command will fill buffer memory with FF value.

3) Perform command: LOAD<enter
Monitor will go to S record reception mode.

4) Select AxIDE UPLOAD operation and select file:12L2p5up.s19 to load.
Select ok.  Use of the "wait for reply character" option is ok.

5) Monitor should indicate "Done" after file is loaded and return
   command prompt/cursor.

6) Perform command: GO 1000<enter

7) After monitor is updated, the "Press RESET switch" prompt 
should appear.  Press the Reset switch and monitor V2.5 should
prompt.

8) Trouble:

  If old monitor prompts again, review procedure and try again
  without deviation.

  If no prompt, procedure has failed and board must be programmed
  with BDM Port. Contact support@axman.com for return instructions.

  